20 research outputs found

    T1 mapping in cardiac MRI

    Get PDF
    Quantitative myocardial and blood T1 have recently achieved clinical utility in numerous pathologies, as they provide non-invasive tissue characterization with the potential to replace invasive biopsy. Native T1 time (no contrast agent), changes with myocardial extracellular water (edema, focal or diffuse fibrosis), fat, iron, and amyloid protein content. After contrast, the extracellular volume fraction (ECV) estimates the size of the extracellular space and identifies interstitial disease. Spatially resolved quantification of these biomarkers (so-called T1 mapping and ECV mapping) are steadily becoming diagnostic and prognostically useful tests for several heart muscle diseases, influencing clinical decision-making with a pending second consensus statement due mid-2017. This review outlines the physics involved in estimating T1 times and summarizes the disease-specific clinical and research impacts of T1 and ECV to date. We conclude by highlighting some of the remaining challenges such as their community-wide delivery, quality control, and standardization for clinical practice

    Outcome and Safety after 103 Radioembolizations with Yttrium-90 Resin Microspheres in 73 Patients with Unresectable Intrahepatic Cholangiocarcinoma—An Evaluation of Predictors

    No full text
    Trans-arterial radioembolization (TARE) is increasingly evaluated for unresectable intrahepatic cholangiocarcinoma (ICC). Not all ICC patients benefit equally well from TARE. Therefore, we sought to evaluate variables predicting progression-free survival (PFS) and overall survival (OS). Patients with non-resectable ICC underwent TARE and were treated with 90Y resin microspheres. Baseline characteristics, biochemical/clinical toxicities, and response were examined for impact on PFS and OS. A total of 103 treatments were administered to 73 patients without major complications or toxicity. Mean OS was 18.9 months (95% confidence intervals (CI); 13.9–23.9 months). Mean and median PFS were 10.1 months (95% CI; 7.9–12.2) and 6.4 months (95% CI; 5.20–7.61), respectively. Median OS and PFS were significantly prolonged in patients with baseline cholinesterase (CHE) ≥ 4.62 kU/L (OS: 14.0 vs. 5.5 months; PFS: 6.9 vs. 3.2 months; p < 0.001). Patients with a tumor burden ≤ 25% had a significantly longer OS (15.2 vs. 6.6 months; p = 0.036). Median PFS was significantly longer for patients with multiple TARE cycles (24.4 vs. 5.8 months; p = 0.04). TARE is a considerable and safe option for unresectable ICC. CA-19-9, CHE, and tumor burden have predictive value for survival in patients treated with TARE. Multiple TARE treatments might further improve survival; this has to be confirmed by further studies

    Accuracy of Calcium Scoring calculated from contrast-enhanced Coronary Computed Tomography Angiography using a dual-layer spectral CT: A comparison of Calcium Scoring from real and virtual non-contrast data.

    No full text
    PurposeModern non-invasive evaluation of Coronary Artery Disease (CAD) requires non-contrast low dose Computed Tomography (CT) imaging for determination of Calcium Scoring (CACS) and contrast-enhanced imaging for evaluation of vascular stenosis. Several methods for calculation of CACS from contrast-enhanced images have been proposed before. The main principle for that is generation of virtual non-contrast images by iodine subtraction from a contrast-enhanced spectral CT dataset. However, those techniques have some limitations: Dual-Source CT imaging can lead to increased radiation exposure, and switching of the tube voltage (rapid kVp switching) can be associated with slower rotation speed of the gantry and is thus prone to motion artefacts that are especially critical in cardiac imaging. Both techniques cannot simultaneously acquire spectral data. A novel technique to overcome these difficulties is spectral imaging with a dual-layer detector. After absorption of the lower energetic photons in the first layer, the second layer detects a hardened spectrum of the emitted radiation resulting in registration of two different energy spectra at the same time. The objective of the present investigation was to evaluate the accuracy of virtual non-contrast CACS computed from spectral data in comparison to standard non-contrast imaging.MethodsWe consecutively investigated 20 patients referred to Coronary Computed Tomography Angiography (CCTA) with suspicion of CAD using a Dual-Layer spectral CT system (IQon; Philips Healthcare, The Netherlands). CACS was calculated from both, real- and virtual non-contrast images by certified software for medical use. Correlation analyses for real- and virtual non-contrast images and agreement evaluation with Bland-Altman-Plots were performed.ResultsMean patient age was 57.7 ± 14 years (n = 20). 13 patients (65%) were male. Inter-quartile-range of clinical CACS was 0-448, the mean was 334. Correlation of CACS from real- and virtual non-contrast images was very high (0.94); p ConclusionDetermination of Calcium Score from contrast enhanced CCTA using spectral imaging with a dual-layer detector is feasible and shows good agreement with the conventional technique when a proportionality factor is applied. The observed difference between both methods is due to an underestimation of plaque volume, and-to an even greater extend -an underestimation of plaque density with the virtual non-contrast approach. Our data suggest that radiation exposure can be reduced through omitting additional native scans for patients referred to CCTA when using a dual-layer spectral system without the usual limitations of dual energy analysis